  1. Markides, C. N. (Ed.)
    Designing air-water systems for industrial applications requires a fundamental understanding of mass accommodation at the liquid-vapor interface, which depends on many factors, including temperature, vapor concentration, and impurities that vary with time. Hence, understanding how mass accommodation changes over a droplet’s lifespan is critical for predicting the performance of applications leveraging evaporation. In this study, experimental data of water droplets on a gold-coated surface evaporating into dry nitrogen is coupled with a computational model to measure the accommodation coefficient at the liquid-vapor interface. We conduct this measurement by combining macroscopic observations with the microscopic kinetic theory of gasses. The experiments utilize a sensitive piezoelectric device to determine the droplet radius with high accuracy and imaging to measure the droplet contact angle. This setup also quantifies the trace amounts of non-volatile impurities in the droplet. For water droplets evaporating in a pure nitrogen stream, the accommodation coefficient directly relates to vapor flux over the droplet’s surface and is affected by the presence of impurities. We obtained a surface-averaged accommodation coefficient close to 0.001 across multiple water droplets evaporating close to room temperature. This quantification can aid in conducting a more accurate analysis of evaporation, which can assist in the improved design of evaporation-based applications. We believe the modeling approach presented in this work, which integrates the kinetic theory of gases to the macroscale flow behavior, can provide a basis for predicting evaporation kinetics in the presence of extremely dry non-condensable gas streams. 
    more » « less
  2. Meyer, J. P. (Ed.)
    Air-water evaporation systems are ubiquitous in industrial applications, including processes such as fuel combustion, inkjet printing, spray cooling, and desalination. In these evaporation-driven systems, a fundamental understanding of mass accommodation at the liquid-vapour interface is critical to predicting and optimizing performance. Interfacial mass accommodation depends on many factors, such as temperature, vapour concentration, non-volatile impurity content, and non-condensable gasses present. Elucidating how these factors interact is essential to designing devices to meet demanding applications. Hence, high precision measurements are needed to quantify accommodation at the liquid-vapour interface accurately. Our previous study has shown surface averaged accommodation coefficients close to 0.001 for pure water droplets throughout evaporation. While it is well established that saline non-volatile impurities reduce the evaporation rate of sessile droplets, the dynamic effect on mass accommodation during the droplet's lifespan is yet to be determined. In this work, we combine experimental and computational techniques to determine the accommodation coefficient over the lifespan of 10-3 to 1 molar potassium chloride-water droplets evaporating on a gold-coated surface into dry nitrogen. This study uses a quartz crystal microbalance as a high-precision contact area sensor. It also determines the non-volatile impurities in the droplet with a precision on the order of nanograms. The computational model couples macroscopic measurements with the microscopic kinetic theory of gasses to quantify hard-to-measure physical quantities. We believe this study will provide a basis for predicting evaporative device performance in conditions where non-volatile impurities are intrinsic to the application. 
    more » « less
  3. Lead (Pb) solubility is commonly limited by dissolution–precipitation reactions of secondary mineral phases in contaminated soils and water. In the research described here, Pb solubility and free Pb2+ ion activities were measured following the precipitation of Pb minerals from aqueous solutions containing sulfate or carbonate in a 1:5 mole ratio in the absence and presence of phosphate over the pH range 4.0–9.0. Using X-ray diffraction and Fourier-transform infrared spectroscopic analysis, we identified anglesite formed in sulfate-containing solutions at low pH. At higher pH, Pb carbonate and carbonate-sulfate minerals, hydrocerussite and leadhillite, were formed in preference to anglesite. Precipitates formed in the Pb-carbonate systems over the pH range of 6 to 9 were composed of cerussite and hydrocerussite, with the latter favored only at the highest pH investigated. The addition of phosphate into the Pb-sulfate and Pb-carbonate systems resulted in the precipitation of Pb3(PO4)2 and structurally related pyromorphite minerals and prevented Pb sulfate and carbonate mineral formation. Phosphate increased the efficiency of Pb removal from solution and decreased free Pb2+ ion activity, causing over 99.9% of Pb to be precipitated. Free Pb2+ ion activities measured using the ion-selective electrode revealed lower values than predicted from thermodynamic constants, indicating that the precipitated minerals may have lower KSP values than generally reported in thermodynamic databases. Conversely, dissolved Pb was frequently greater than predicted based on a speciation model using accepted thermodynamic constants for Pb ion-pair formation in solution. The tendency of the thermodynamic models to underestimate Pb solubility while overestimating free Pb2+ activity in these systems, at least in the higher pH range, indicates that soluble Pb ion-pair formation constants and KSP values need correction in the models. 
    more » « less
  4. We study decomposition of geometrically enforced nematic topological defects bearing relatively large defect strengths m in effectively two-dimensional planar systems. Theoretically, defect cores are analyzed within the mesoscopic Landau - De Gennes approach in terms of the tensor nematic order parameter. We demonstrate a robust tendency of defect decomposition into elementary units where two qualitatively different scenarios imposing total defect strengths to a nematic region are employed. Some theoretical predictions are verified experimentally, where arrays of defects bearing charges m = ±1, and even m = ±2, are enforced within a plane-parallel nematic cell using an AFM scribing method. 
    more » « less